Safety Laser Scanner SZ-V32NC (X)

$6,198.99

Model: SZ-V32NC 

Type: Network Type (CIP Safety)

Description

Model SZ-V32NC *1
Type Network Type (CIP Safety)
Detection capability Minimum detectable object size Diameter 20, 30, 40, 50, 70, 150 mm 0.79″, 1.18″, 1.57″, 1.97″, 2.76″, 5.91″ (depends on the setting) Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max. *2
Detectable angle 190° ( -5° to 185° )
Response time (ON to OFF) Standard Mode Scan Cycle A 160 ms (2scans) to 1280 ms (16scans) *3 *4
Scan Cycle B 168 ms (2scans) to 1344 ms (16scans) *3 *4
Scan Cycle C 176 ms (2scans) to 1408 ms (16scans) *3 *4
High Speed Mode Scan Cycle A 80 ms (2scans) to 640 ms (16scans) *3 *4
Scan Cycle B 84 ms (2scans) to 672 ms (16scans) *3 *4
Scan Cycle C 88 ms (2scans) to 704 ms (16scans) *3 *4
Response time (OFF to ON) Response time (ON to OFF) + 150 ms
Protection zone Minimum detectable object size: 70 / 150 mm 2.76″ / 5.91″ 8.4 m 27.56′ (Standard Mode) 5.7 m 18.70′ (High Speed Mode)
Minimum detectable object size: 50 mm 1.97″ 5.6 m 18.37′ (Standard Mode) 3.8 m 12.47′ (High Speed Mode)
Minimum detectable object size: 40 mm 1.57″ 4.3 m 14.11′ (Standard Mode) 2.9 m 9.51′ (High Speed Mode)
Minimum detectable object size: 30 mm 1.18″ 2.9 m 9.51′ (Standard Mode) 2.0 m 6.56′ (High Speed Mode)
Minimum detectable object size: 20 mm 0.79″ 1.6 m 5.25′ (Standard Mode) 1.1 m 3.61′ (High Speed Mode)
Warning zone Minimum detectable object size: 70 / 150 mm 2.76″ / 5.91″ 26 m 85.30′ (Standard Mode) 23 m 75.46′ (High Speed Mode) *5
Minimum detectable object size: 50 mm 1.97″ 25 m 82.02′ (Standard Mode) 21 m 68.90′ (High Speed Mode) *5
Minimum detectable object size: 40 mm 1.57″ 24 m 78.74′ (Standard Mode) 20 m 65.62’ (High Speed Mode) *5
Minimum detectable object size: 30 mm 1.18″ 23 m 75.46′ (Standard Mode) 18 m 59.06′ (High Speed Mode) *5
Minimum detectable object size: 20 mm 0.79″ 21 m 68.90′ (Standard Mode) 15 m 49.21′ (High Speed Mode) *5
Additional safety distance 100 mm 3.94″ *6
Maximum measurement distance 60 m 196.85′ *7
Maximum number of banks Max.16 banks
Multiple scanner heads Max. 3 scanner heads
Camera monitoring area Monitor area: over 190° (-5° to 185°) *8
Display QVGA 2.2inch color LCD
Light source Type, wavelength Infrared laser diode, 905 nm
Laser Class IEC Class1 IEC/EN60825-1
FDA Class1 FDA 21CFR 1040.10, 1040.11 (Laser Notice No.50) *9
JIS Class1 JIS C6802
Control output (OSSD) Output
Number of outputs
Max. load current
Residual voltage (during ON)
OFF-state voltage
Leakage current
Max. capacitive load
Load wiring resistance
Inputs PNP
NPN
Non-safety related output (AUX output) Output type
Number of outputs
Max. load current
Residual voltage (during ON)
Muting lamp
Interface USB USB2.0
Ethernet Standard IEEE802.3u (100 BASE-TX)
Transmission rate 100 Mbps
Cable STP(Shielded Twisted Pair)
cable or UTP(Unshielded Twisted Pair) cable. Category5 or higher.
Connector RJ45 (IP65) 2 ports
Network function CIP Safety, EtherNet/IP®, UDP
Cable length Power and I/O cable 30 m 98.43′ or less *10
Between scanner head and display unitc 20 m 65.62′ or less each *11
Ethernet cable 100 m 328.08′ or less *12
Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE)
EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA
Safety IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR), IEC61508, EN61508,
EN ISO13849-1, 2015 (PLd, Category3), UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8
Rating Power consumption 13.4 W
Power voltage 24 VDC ±10% (Ripple P-P 10% or less): When using a converter power supply, 24 VDC +20%/-30%: When using a battery
Environmental resistance Enclosure rating IP65(IEC60529)
Ambient light Incandescent lamp: 1500 lux or less *13
Operating ambient temperature -10 to +50°C 14 to 122°F (No freezing)
Storage temperature -25 to +60°C -13 to +140°F (No freezing)
Operating relative humidity 35% to 85% RH (No condensation)
Storage relative humidity 35% to 95% RH
Vibration resistance 10 to 55 Hz, 0.7 mm 0.03″ compound amplitude, 20 sweeps each in X, Y, and Z directions
Shock resistance 100 m/s2 328.08 ft/s2 (Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1000 times each axis
Material Scanner head Main unit case Magnesium
Window Polycarbonate, PEI
Indicator part Aluminum, PES
Display unit Case Magnesium, PPS, Polycarbonate
System memory Aluminum, PPE
Weight Approx. 2300 g
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005).
*2 If the object to be detected moves parallel to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s 5.25 ft/s, regardless of the encoder setting.
*3 The response time, protection zone, and warning zone are affected by the operation mode.
*4 When using PROFIsafe, 6 ms is added to the response time. When using CIP Safety, 10ms is added to the response time.
*5 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
*6 If there is a highly reflective background within 1.5 m 4.92′ from the boundary of the protection zone, 200 mm 7.87″ must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance.
*7 Even when using the network data output, the maximum measured output distance is 60 m 196.85′.
*8 Only applicable for the type with a camera.
*9 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*10 10 m 32.81′ or less when supplying power from a battery.
*11 When supplying power from a battery, the length of each connection cable should be 10 m 32.81′ or less when using two scanner heads, and 5 m 16.40′ or less when using three scanner heads.
*12 Distance between SZ-V and Ethernet switch.
*13 An ambient light source should not be located within ±5° of the detection plane.

Additional information

Weight 5.50 lbs

Reviews

There are no reviews yet.

Be the first to review “Safety Laser Scanner SZ-V32NC (X)”